6.9
CVE-2024-35212 -
A vulnerability has been identified in SINEC Traffic Analyzer (6GK8822-1BG01-0BA0) (All versions < V1.2). The affected application lacks input validation due to which an attacker can gain access to the Database entries.
6.8
CVE-2024-35211 -
A vulnerability has been identified in SINEC Traffic Analyzer (6GK8822-1BG01-0BA0) (All versions < V1.2). The affected web server, after a successful login, sets the session cookie on the browser, without applying any security attributes (such as βSecureβ, βHttpOnlyβ, or βSameSiteβ).
5.1
CVE-2024-35210 -
A vulnerability has been identified in SINEC Traffic Analyzer (6GK8822-1BG01-0BA0) (All versions < V1.2). The affected web server is not enforcing HSTS. This could allow an attacker to perform downgrade attacks exposing confidential information.
6.9
CVE-2024-35209 -
A vulnerability has been identified in SINEC Traffic Analyzer (6GK8822-1BG01-0BA0) (All versions < V1.2). The affected web server is allowing HTTP methods like PUT and Delete. This could allow an attacker to modify unauthorized files.
4.8
CVE-2024-35208 -
A vulnerability has been identified in SINEC Traffic Analyzer (6GK8822-1BG01-0BA0) (All versions < V1.2). The affected web server stored the password in cleartext. This could allow attacker in a privileged position to obtain access passwords.
8.5
CVE-2024-35207 -
A vulnerability has been identified in SINEC Traffic Analyzer (6GK8822-1BG01-0BA0) (All versions < V1.2). The web interface of the affected devices are vulnerable to Cross-Site Request Forgery(CSRF) attacks. By tricking an authenticated victim user to click a malicious link, an attacker could perfoβ¦
8.5
CVE-2024-35206 -
A vulnerability has been identified in SINEC Traffic Analyzer (6GK8822-1BG01-0BA0) (All versions < V1.2). The affected application does not expire the session. This could allow an attacker to get unauthorized access.
7.4
CVE-2024-33500 -
A vulnerability has been identified in Mendix Applications using Mendix 10 (All versions < V10.11.0), Mendix Applications using Mendix 10 (V10.6) (All versions < V10.6.9), Mendix Applications using Mendix 9 (All versions >= V9.3.0 < V9.24.22). Affected applications could allow users with the capabiβ¦
6.9
CVE-2023-50763 -
A vulnerability has been identified in SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions < V2.3), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions < V2.3), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (Alβ¦
4.8
CVE-2023-38533 -
A vulnerability has been identified in TIA Administrator (All versions < V3 SP2). The affected component creates temporary download files in a directory with insecure permissions. This could allow any authenticated attacker on Windows to disrupt the update process.