Description

Bio-Formats versions up to and including 8.3.0 contain an XML External Entity (XXE) vulnerability in the Leica Microsystems metadata parsing component (e.g., XLEF). The parser uses an insecurely configured DocumentBuilderFactory when processing Leica XML-based metadata files, allowing external entity expansion and external DTD loading. A crafted metadata file can trigger outbound network requests (SSRF), access local system resources where readable, or cause a denial of service during XML parsing.

INFO

Published Date :

2026-01-07T20:26:48.324Z

Last Modified :

2026-03-18T16:45:21.535Z

Source :

VulnCheck
AFFECTED PRODUCTS

The following products are affected by CVE-2026-22186 vulnerability.

Vendors Products
Openmicroscopy
  • Bio-formats

CVSS Vulnerability Scoring System

Detailed values of each vector for above chart.
Attack Vector
Attack Complexity
Attack Requirements
Privileges Required
User Interaction
VS Confidentiality
VS Integrity
VS Availability
SS Confidentiality
SS Integrity
SS Availability
Detailed values of each vector for above chart.
Attack Vector
Attack Complexity
Privileges Required
User Interaction
Scope
Confidentiality Impact
Integrity Impact
Availability Impact