Description

The Access Manager 92xx in hardware revision K7 is based on Linux instead of Windows CE embedded in older hardware revisions. In this new hardware revision it was noticed that an SSH service is exposed on port 22. By analyzing the firmware of the devices, it was noticed that there are two users with hardcoded and weak passwords that can be used to access the devices via SSH. The passwords can be also guessed very easily. The password of at least one user is set to a random value after the first deployment, with the restriction that the password is only randomized if the configured date is prior to 2022. Therefore, under certain circumstances, the passwords are not randomized. For example, if the clock is never set on the device, the battery of the clock module has been changed, the Access Manager has been factory reset and has not received a time yet.

INFO

Published Date :

2026-01-26T10:05:45.768Z

Last Modified :

2026-01-26T15:13:19.837Z

Source :

SEC-VLab
AFFECTED PRODUCTS

The following products are affected by CVE-2025-59103 vulnerability.

Vendors Products
Dormakaba
  • Access Manager
REFERENCES

Here, you will find a curated list of external links that provide in-depth information to CVE-2025-59103.

CVSS Vulnerability Scoring System

Detailed values of each vector for above chart.
Attack Vector
Attack Complexity
Attack Requirements
Privileges Required
User Interaction
VS Confidentiality
VS Integrity
VS Availability
SS Confidentiality
SS Integrity
SS Availability