Description

A stack-based buffer overflow vulnerability exists in the MFER parsing functionality of The Biosig Project libbiosig 3.9.0 and Master Branch (35a819fa). A specially crafted MFER file can lead to arbitrary code execution. An attacker can provide a malicious file to trigger this vulnerability.This vulnerability manifests on line 9184 of biosig.c on the current master branch (35a819fa), when the Tag is 131: else if (tag==131) //0x83 { // Patient Age if (len!=7) fprintf(stderr,"Warning MFER tag131 incorrect length %i!=7\n",len); curPos += ifread(buf,1,len,hdr);

INFO

Published Date :

2025-08-25T13:53:46.822Z

Last Modified :

2025-08-25T18:22:08.119Z

Source :

talos
AFFECTED PRODUCTS

The following products are affected by CVE-2025-54493 vulnerability.

Vendors Products
The Biosig Project
  • Libbiosig
REFERENCES

Here, you will find a curated list of external links that provide in-depth information to CVE-2025-54493.

CVSS Vulnerability Scoring System

Detailed values of each vector for above chart.
Attack Vector
Attack Complexity
Privileges Required
User Interaction
Scope
Confidentiality Impact
Integrity Impact
Availability Impact