Description

A NULL Pointer Dereference vulnerability in the flow daemon (flowd) of Juniper Networks Junos OS on SRX Series allows an attacker causing specific, valid control traffic to be sent out of a Dual-Stack (DS) Lite tunnel to crash the flowd process, resulting in a Denial of Service (DoS).  Continuous triggering of specific control traffic will create a sustained Denial of Service (DoS) condition. On all SRX platforms, when specific, valid control traffic needs to be sent out of a DS-Lite tunnel, a segmentation fault occurs within the flowd process, resulting in a network outage until the flowd process restarts. This issue affects Junos OS on SRX Series: * All versions before 21.2R3-S9, * from 21.4 before 21.4R3-S9, * from 22.2 before 22.2R3-S5, * from 22.4 before 22.4R3-S6, * from 23.2 before 23.2R2-S3, * from 23.4 before 23.4R2.

INFO

Published Date :

2025-04-09T19:52:51.730Z

Last Modified :

2025-04-24T20:04:34.131Z

Source :

juniper
AFFECTED PRODUCTS

The following products are affected by CVE-2025-30645 vulnerability.

Vendors Products
Juniper
  • Junos
  • Srx1500
  • Srx1600
  • Srx2300
  • Srx300
  • Srx320
  • Srx340
  • Srx345
  • Srx380
  • Srx4100
  • Srx4120
  • Srx4200
  • Srx4300
  • Srx4600
  • Srx4700
  • Srx5400
  • Srx5600
  • Srx5800
REFERENCES

Here, you will find a curated list of external links that provide in-depth information to CVE-2025-30645.

CVSS Vulnerability Scoring System

Detailed values of each vector for above chart.
Attack Vector
Attack Complexity
Attack Requirements
Privileges Required
User Interaction
VS Confidentiality
VS Integrity
VS Availability
SS Confidentiality
SS Integrity
SS Availability
Detailed values of each vector for above chart.
Attack Vector
Attack Complexity
Privileges Required
User Interaction
Scope
Confidentiality Impact
Integrity Impact
Availability Impact