Description
An optional feature of PCI MSI called "Multiple Message" allows a device to use multiple consecutive interrupt vectors. Unlike for MSI-X, the setting up of these consecutive vectors needs to happen all in one go. In this handling an error path could be taken in different situations, with or without a particular lock held. This error path wrongly releases the lock even when it is not currently held.
INFO
Published Date :
2024-07-18T13:31:31.244Z
Last Modified :
2025-04-26T20:03:16.232Z
Source :
XEN
AFFECTED PRODUCTS
The following products are affected by CVE-2024-31143 vulnerability.
| Vendors | Products |
|---|---|
| Xen |
|
REFERENCES
Here, you will find a curated list of external links that provide in-depth information to CVE-2024-31143.
CVSS Vulnerability Scoring System
Detailed values of each vector for above chart.
Attack Vector
Attack Complexity
Privileges Required
User Interaction
Scope
Confidentiality Impact
Integrity Impact
Availability Impact