Description
Triangle MicroWorks SCADA Data Gateway GTWWebMonitorService Unquoted Search Path Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute code on affected installations of Triangle MicroWorks SCADA Data Gateway. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed. The specific flaw exists within the configuration of the GTWWebMonitorService service. The path to the service executable contains spaces not surrounded by quotations. An attacker can leverage this vulnerability to execute arbitrary code in the context of root. Was ZDI-CAN-20538.
INFO
Published Date :
2024-05-03T01:59:27.382Z
Last Modified :
2024-08-02T18:10:20.680Z
Source :
zdi
AFFECTED PRODUCTS
The following products are affected by CVE-2023-39464 vulnerability.
| Vendors | Products |
|---|---|
| Trianglemicroworks |
|
REFERENCES
Here, you will find a curated list of external links that provide in-depth information to CVE-2023-39464.